SOFCOT 2024
Active participation in the latest SOFCOT congress from November 11 to 13, 2024 for all the team in several symposia, moderation, instructional course lecture and oral communication.
Christophe Charousset reported comparison of clinical and radiographic out- comes with minimum 3-year follow-up of the first study comparing ISA Inlay versus ISA Onlay humerus design in Reverse Total Shoulder Arthroplasty with same Neck Shoulder Angle of 145° and same glenoid implant ISA reverse developed by SFI and MoveUp.
In conclusion we found no difference for Constant score, SSV, forward elevation, external rotation at side, internal rotation and radiographic loosening and stress shielding. External rotation with 90° abduction was better for ISA Onlay humerus design but the majority of malaligned components were implanted in valgus for ISA Onlay
Before choosing which humeral design, you want to use, it's important to know the characteristics of each implant and to use computer assisted as a decision aid.